High quality cleanroom pharma manufacturer

Manufacturing

Quality clean room in pharmaceutical industry manufacturer factory: The connection between the wall and the floor and the ceiling should be in a concave arc shape, without gaps, leaving no dead corners. The aseptic operation room should have a unidirectional air device for air sterilization filtration, a super-clean workbench with a cleanliness of 100 or the same level, indoor temperature control of 18-26 ℃, and relative humidity of 45%-65%. The buffer room and the operating room should be equipped with UV lamps or other appropriate disinfection devices that can achieve the effect of air disinfection. The static pressure difference between adjacent rooms with different air cleanliness levels should be greater than 5Pa, and the static pressure difference between the clean room (area) and the outdoor atmosphere should be greater than 10Pa. The lighting in the aseptic room should be embedded in the ceiling, the indoor light should be evenly distributed, and the illuminance is not less than 300lx. Discover more info on tablet punches and dies.

Laboratory furniture, laboratory test equipment, including fume hood, experimental cabinet, storage cabinet, etc. According to the material classification, including all steel, all wood, steel wood, aluminum wood, stainless steel, PP and other types. For biology, medicine, coating laboratory and clean room, thorough cleaning and disinfection is the first function to be considered, which requires the laboratory furniture to be easy to clean, disinfect and keep clean for a long time.

Labeller is a device that pastes rolled self-adhesive paper labels (paper or metal foil) onto PCB, products or specified packaging. It has a wide range of applications, and can meet the full circle labeling or semi circle labeling of round bottles. The labeling switching between bottles is simple and easy to adjust. Blister packaging machine is a machine that uses transparent plastic film or sheet to form a blister and seals the product between the blister and the bottom plate by means of heat sealing and bonding. Application: capsule, plain tablet, sugar coating, capsule, injection, abnormity, etc., as well as sealed packaging of medical devices, light food, electronic components blister.

In summary, maintaining the right humidity level in clean rooms is vital for ensuring their effectiveness and longevity. By understanding the normal humidity range for clean rooms (between 40% and 60% RH) and implementing proper cleanroom humidity control techniques such as using a dehumidifier, hygrometer, proper ventilation, and controlling water sources, professionals can help create a controlled environment that promotes optimal performance and safety.

The plane and space design of the clean laboratory will arrange the clean experimental area and personnel purification, equipment and material purification and other auxiliary rooms in different areas. At the same time, the comprehensive coordination effects of various technical facilities, such as experimental operation, process equipment installation and maintenance, air distribution type, pipeline layout and purified air conditioning system, are considered.

For the tuyere equipped with filter, the auxiliary air duct can be selected according to the tuyere form, that is, the straight pipe section with the same section as the tuyere and the length equal to twice the side length of the tuyere is made of hard plate, which is connected to the outside of the filter tuyere. The measuring points are evenly arranged on the outlet plane of the auxiliary air duct according to the minimum number of measuring points, and the wind speed of each point is measured with a hot ball anemometer. The air volume is determined by multiplying the average wind speed at the section of the air outlet by the net section area of the air outlet.

A clean room is defined as a room with air filtration, distribution, optimization, construction materials and devices, where specific regular operating procedures are used to control airborne particulate concentrations to achieve an appropriate level of particulate cleanliness. A clean room refers to the removal of particulates, harmful air, bacteria and other pollutants in the air within a certain space, and the indoor temperature, cleanliness, indoor pressure, airflow speed and airflow distribution, noise vibration and lighting, static electricity. A specially designed room that is controlled within a certain demand range. Read additional info at sz-pharma.com.

High quality tablet punches and dies wholesale manufacturer and supplier: Generally, the air flow distribution point on the surface of the operating table or production equipment should be located at 2/3 of the distance between the clean room space and the partition wall, so that when the operator is working, the air flow can flow from the inside of the process area to the operation area, and the The dust is taken away; if the distribution point is arranged in front of the process area, it will become an improper airflow distribution. At this time, most of the air flow will flow to the process area, and the dust caused by the operator’s operation will be brought to the back of the equipment. As a result, the platform will be polluted, and the yield rate is bound to decrease.

Clean shed, also known as clean work shed (dust-free shed, purification shed, operating table, etc.), is a small space surrounded by anti-static mesh curtains or plexiglass in the clean room, and HEPA and FFU air supply units are used above. It is composed of a space with a higher purification level than the clean room, and the clean room can be equipped with purification equipment such as air shower room and transfer window.