Pill stamp press supplier today: The Importance of Clean Rooms: Clean rooms are designed to minimize the presence of dust, bacteria, viruses, and other contaminants that could affect product quality or pose health hazards to workers. By controlling factors such as temperature, humidity, air circulation, and cleaning methods, clean rooms help ensure that products manufactured within these environments meet strict regulatory requirements and are safe for use by consumers. The International Organization for Standardization (ISO) has developed a series of standards that outline the requirements for clean room design, construction, operation, and maintenance. The most commonly used ISO code for clean rooms is ISO 14644-1: 2015, which specifies the general layout and requirements for cleanroom facilities intended for use with biological samples. This standard covers various aspects of clean room design, including the selection of materials, installation of equipment, and management of environmental factors. Read extra information on pharma machinery.

Tablet press is mainly used for tablet technology research in pharmaceutical industry. The tablet pressing machine presses powder or granular raw materials into tablets. Its scope of application: Traditional Chinese medicine, western medicine, health products, food, chemical industry, electronics and other industries. The prefabricated container house is a new concept of environmentally friendly and economical house with light steel H-shaped steel and channel steel as the framework, sandwich panel as the wallboard material, space combination with standard modulus series, and bolted or welded components.

V-type mixer series products are high-efficiency asymmetric mixers, which are applicable to the mixing of powder particles with good material fluidity and small physical property differences, as well as the mixing of materials with low mixing degree and short mixing time. Since the flow of materials in the V-type mixing container is stable and will not damage the original shape of materials, the V-type mixer is also applicable to the mixing of granular materials that are easy to break and wear, or fine powder particles, blocks. It is widely used in pharmaceutical, chemical, food and other industries.

In summary, maintaining the right humidity level in clean rooms is vital for ensuring their effectiveness and longevity. By understanding the normal humidity range for clean rooms (between 40% and 60% RH) and implementing proper cleanroom humidity control techniques such as using a dehumidifier, hygrometer, proper ventilation, and controlling water sources, professionals can help create a controlled environment that promotes optimal performance and safety.

The plane and space design of the clean laboratory will arrange the clean experimental area and personnel purification, equipment and material purification and other auxiliary rooms in different areas. At the same time, the comprehensive coordination effects of various technical facilities, such as experimental operation, process equipment installation and maintenance, air distribution type, pipeline layout and purified air conditioning system, are considered.

For the air outlet equipped with similar diffuser, the air volume can be found out according to the air volume resistance curve of diffuser (factory air volume resistance curve or field measured air volume resistance curve) and the measured diffuser resistance (the difference between the static pressure in the orifice and the indoor pressure). When measuring, use a micro manometer and a fine pitot tube, or use a fine rubber tube to replace the pitot tube, but the plane of the measuring hole must be parallel to the air flow direction. In addition, other methods approved by the professional testing department can also be used.

Airflow is the most important factor in controlling cleanliness and temperature and humidity, and it also has some influence on noise. Therefore, the wind speed measurement is the first step in the clean room test. The purpose of the wind speed measurement is to confirm that the air flow sent by the filter meets the design specifications, and the second is to confirm the uniformity of the air flow. In some occasions, due to site restrictions, the indoor ventilation volume must also be converted by multiplying the wind speed by the outlet area. Discover even more information on https://www.sz-pharma.com/.

Excellent tablet press dies manufacturer and supplier: Generally, the air flow distribution point on the surface of the operating table or production equipment should be located at 2/3 of the distance between the clean room space and the partition wall, so that when the operator is working, the air flow can flow from the inside of the process area to the operation area, and the The dust is taken away; if the distribution point is arranged in front of the process area, it will become an improper airflow distribution. At this time, most of the air flow will flow to the process area, and the dust caused by the operator’s operation will be brought to the back of the equipment. As a result, the platform will be polluted, and the yield rate is bound to decrease.

A clean room refers to the removal of particulates, harmful air, bacteria and other pollutants in the air within a certain space, and the indoor temperature, cleanliness, indoor pressure, airflow speed and airflow distribution, noise vibration and lighting, Static control is within a certain demand range, and a specially designed room is given. That is to say, no matter how the external air conditions change, the interior can maintain the characteristics of cleanliness, temperature, humidity and pressure that were originally set. The main function of the clean room is to control the cleanliness and temperature and humidity of the atmosphere that the product comes into contact with, so that the product can be produced and manufactured in a good environmental space. We call such a space a clean room.