Pill stamp press supplier today: Clean room equipment includes air purification equipment and air ventilation equipment. During the construction process, it is necessary to select the appropriate air filtration equipment according to specific practical needs. In general, the selection of air purification equipment will use coupled filtration technology to achieve the purpose of eliminating dust in the air, that is, through multiple layers of different filtration forms, to eliminate foreign particles and harmful substances in the air. See more information at tablet punches and dies.

The connection between the wall and the floor and the ceiling should be in a concave arc shape, without gaps, leaving no dead corners. The aseptic operation room should have a unidirectional air device for air sterilization filtration, a super-clean workbench with a cleanliness of 100 or the same level, indoor temperature control of 18-26 ℃, and relative humidity of 45%-65%. The buffer room and the operating room should be equipped with UV lamps or other appropriate disinfection devices that can achieve the effect of air disinfection. The static pressure difference between adjacent rooms with different air cleanliness levels should be greater than 5Pa, and the static pressure difference between the clean room (area) and the outdoor atmosphere should be greater than 10Pa. The lighting in the aseptic room should be embedded in the ceiling, the indoor light should be evenly distributed, and the illuminance is not less than 300lx.

V-type mixer series products are high-efficiency asymmetric mixers, which are applicable to the mixing of powder particles with good material fluidity and small physical property differences, as well as the mixing of materials with low mixing degree and short mixing time. Since the flow of materials in the V-type mixing container is stable and will not damage the original shape of materials, the V-type mixer is also applicable to the mixing of granular materials that are easy to break and wear, or fine powder particles, blocks. It is widely used in pharmaceutical, chemical, food and other industries.

Efficiency of Equipment: Some equipment, such as electronics and mechanical components, require specific humidity levels to function correctly. Maintaining the right humidity levels in clean rooms ensures optimal performance and longevity of these critical pieces of equipment. How to Maintain Optimal Humidity Levels in Clean Rooms? To maintain optimal humidity levels in clean rooms, consider the following steps: Install a Dehumidifier: A dehumidifier is an essential tool for maintaining proper humidity levels in clean rooms. It removes excess moisture from the air, keeping humidity levels within the desired range. Choose a dehumidifier based on the size of your clean room and the relative humidity requirements you need to meet.

Mainly control the pollution of air dust particles and organisms (bacteria) to working objects, and maintain a negative pressure with the atmosphere inside. Pharma cleanroom project It is suitable for precision machinery industry, electronics industry, aerospace industry, high-purity chemical industry, atomic energy industry, optomagnetic product industry, LCD, computer hard disk; pharmaceutical industry, hospital, operating room, sterile ward, food, cosmetics, beverage products Animal laboratory, physical and chemical laboratory, blood station, etc. More cases check our cleanroom project page.

For the unidirectional flow (laminar flow) clean room, the air supply volume is determined by the product of the average wind speed of the room section and the cross-sectional area, in which the measured section of the vertical unidirectional flow (laminar flow) clean room is the horizontal section 0.8m away from the ground; The horizontal unidirectional flow (laminar flow) clean room takes a vertical section 0.5m away from the air supply surface. The spacing of measuring points on the section shall not be greater than 2m, and the number of measuring points shall not be less than 10, which shall be evenly arranged. Hot bulb anemometer for instrument.

High quality pill stamp press manufacturer and supplier: Today (Suzhou Pharma Machinery Co., Ltd.) will introduce to you, clean room airflow and influencing factors. There are many factors affecting the airflow in the clean room, such as process equipment, personnel, clean room assembly materials, lighting fixtures, etc. At the same time, the distribution point of airflow above the production equipment should also be considered.

The frame of the clean shed can be generally divided into three types: stainless steel square pass, varnished iron square pass and industrial aluminum profiles. The top and the top can be made of stainless steel steel plate, lacquered cold plastic steel plate, anti-static mesh curtain and acrylic plexiglass and other materials. Anti-static mesh curtains or plexiglass are generally used around, and FFU clean air supply units are used in the air supply unit.

Suzhou Pharma is one of the leading turnkey project providers for pharmaceutical, food, herbal, cosmetic, electronics factory and chemical plants. We offer projects as per GMP regulations. As being pioneers in this field, the solutions from Suzhou Pharma is readily accepted by the customers. Our solid expertise in cleanroom allows meeting the precise needs of its customer’s industry in different sectors such as health,pharmaceutical, biotechnology, and cosmetics. We firmly believe in the principle of quality by design. See additional information on https://www.sz-pharma.com/.